Аттракционы · РЕШЕНИЯ ДЛЯ ПАРКОВ · ДОСТАВКА ПО ВСЕМУ МИРУ
ГИДЫ

Высота башни падения: Что вы можете построить на своем сайте

Каждый проект вертикального аттракциона затрагивает один и тот же ранний вопрос.: что высота опускаемой башни will the site support? The answer is not simply the tallest model that fits inside the property boundary. Height affects planning approval, structural loads, проектирование фундамента, воздействие ветра, lifting, груз, inspection and the emergency plan.

DINIS builds three rotating tower models and the 63 м свободное падение. Their marketed names and engineering heights are not always identical. А 15 m tower has a 16.9 структура м и 12.5 м рабочая высота; тот 35 m model has a 32.4 структура м и 28.5 м рабочая высота. Both figures must appear in the project discussion because the planning authority, structural engineer and operator use different measurements.

Аттракцион с откидной башней, установленный на открытом воздухе, с вращающейся гондолой
Аттракцион с башней установлен в открытом парке развлечений

Высота башни падения: structure height vs operating height

Structure height is the physical equipment dimension used for site planning and approval. Operating height is the highest position used by the ride cycle. Do not use the model number as either measurement.

Модель Высота конструкции Рабочая высота Equipment footprint Всадники Установленная мощность Height-specific planning point
15 м вращающаяся башня 16.9 м 12.5 м 8 х 8 м 12 40 кВт Most suitable compact model for indoor or tightly planned sites, subject to finished clear height.
25 м вращающаяся башня 25 м 19.5 м 9 х 9 м 16 70 кВт First outdoor landmark for many family and city parks.
35 м вращающаяся башня 32.4 м 28.5 м 11 х 8 м 16 90 кВт Taller landmark with dual hydraulic cylinders and a larger delivery package.
63 м свободное падение 63 м 52 м 15 х 15 м 32 520 кВт Major attraction requiring dedicated structural, electrical, lifting and emergency planning.

The working height should be confirmed on the approved general arrangement drawing. Ask whether the authority measures the structure, lightning rod, antenna or any rooftop beacon, and confirm the exact reference height used in the permit application.

Why the model name and engineering height differ

Model names are commercial labels. А 15 м, 25 м, 35 м и 63 m names help buyers compare the range, but the technical package contains the actual structure and operating figures. А 35 m model is a clear example: it is marketed as 35 м, has a 32.4 m equipment height and reaches 28.5 m during operation.

Use the engineering drawing for foundations, clearances, crane planning and approvals. Using the model label without checking the detail can either overstate the site requirement or, more dangerously, understate the foundation and lifting scope.

Start with the maximum permitted height

Before choosing a ride, obtain the maximum structure height allowed on the exact plot. The limit may come from zoning, airport or flight-path restrictions, heritage sightlines, local amusement-device rules, building height limits or the property owner’s requirements.

16.9 мstructure height of the compact rotating tower
25 мstructure height of the mid-range outdoor model
32.4 мengineering height of the 35 м модель
63 мstructure height of the current free fall

If the approved limit is 18 м, тот 15 m model may fit and the 25 m model does not. Если предел 30 м, тот 35 m model is outside the structure limit even though its commercial name is often treated as the same number. Establish the permitted height in writing before ordering the foundation design.

Утверждение высоты: the five practical stages

  1. Pre-application review

    Отправить сюжет, permitted use, maximum height, nearby buildings, roads, flight paths and any local amusement-device requirements to the relevant authorities.

  2. Model and site-envelope selection

    Match the structure and operating heights to the site, then add the queue, entry and exit, maintenance access, emergency route and lifting area.

  3. Technical documentation

    Prepare the general arrangement, foundation loads, anchor positions, electrical data, manuals and inspection documents required for local review.

  4. Foundation and installation approval

    The local structural engineer designs the foundation from the final loads. Civil work, положение крана, power connection and assembly are then completed against approved drawings.

  5. Testing and operating handover

    Complete no-load and loaded tests, verify emergency functions and hand over inspection records, manuals, spare list and operator training before the ride opens.

Requirements vary by country and city. The list above is a project checklist, not a substitute for the local approval process or the authority’s written requirements.

What changes between 15 м и 63 м

Foundation and structural loads

The foundation must be designed for the selected model, soil conditions, groundwater, local wind requirements and the manufacturer’s anchor layout. А 63 m free fall has a completely different structural and geotechnical package from a 15 м вращающаяся башня; a generic concrete slab is not a foundation design.

Wind exposure and operating rules

Height and open site exposure increase the importance of wind monitoring, shutdown criteria, storm preparation and post-storm inspection. Use the operating limits in the approved manual and the site-specific risk assessment rather than assuming one wind limit applies to every country or installation.

Lightning and electrical protection

Confirm lightning protection, earthing and the location of the control system. The installed power range runs from 40 кВт на 15 m tower to 520 кВт на 63 м свободное падение, so the transformer, cable route, switchgear and control room must follow the selected model.

Груз, lifting and installation

Taller structures are split into more transportable sections. А 15 m model is listed with two 40HQ containers at about 11.5 т; тот 35 m model is listed with three 40HQ containers at about 22.6 т. Confirm the final packing list and lifting plan with the quotation because cabin, тема, enclosure and destination can change logistics.

Emergency planning and maintenance access

Define the rescue route, operator position, access for maintenance and emergency services, and the procedure for a stopped ride at height. These items belong in the site drawing before construction starts, not in a conversation after the equipment arrives.

Indoor drop tower clearance

The compact tower can be considered for a covered site, but the finished building clear height must exceed the full structure height and leave room for installation, maintenance, освещение, roof structure and any protection system. Do not compare the 12.5 m operating height with the ceiling height and assume the 16.9 m structure will fit.

  • Finished floor-to-lowest-obstruction height after beams, ducts, lighting and sprinklers.
  • Floor loading and the route used to move the heaviest sections into the building.
  • Opening sizes, crane or forklift access and temporary protection for the finished floor.
  • Queue, entry, exit, operator position and emergency evacuation away from the ride envelope.
  • Electrical room, isolator, cable route and protection against water or accidental contact.

Outdoor drop tower site envelope

The equipment footprint is only one part of the plot. The approved layout should also show the safety boundary, изгородь, очередь, gates, operator station, maintenance access, foundation projection, drainage, crane position and delivery route.

For roadside or city-centre sites, add sightlines from neighbouring properties, шум, lighting spill, traffic and emergency access. For park sites, coordinate the height with the master plan, surrounding attractions, landscaping and any future expansion.

Documents to prepare before the order

SITE

Survey and plan

Boundary survey, plot dimensions, levels, access roads, nearby buildings and the intended ride position.

APPROVAL

Height and use

Permitted use, maximum structure height, local amusement-device requirements and any aviation, heritage or sightline restrictions.

GROUND

Geotechnical data

Soil report, groundwater information, existing services and the loading assumptions required by the local structural engineer.

POWER

Electrical capacity

Available voltage and phase, transformer capacity, cable route, earthing arrangement and the final installed load.

Can a drop tower be extended later?

Extending the height of an installed tower is not a normal field modification. The structure, hydraulic system, водить машину, фундамент, manufacturer’s approved design, inspection file and planning approval may all change. Moving an existing ride to another site can be evaluated, but a taller new ride should normally be planned and purchased as a complete model.

Questions buyers ask about drop tower height

01

What is the tallest drop tower in the range?

А 63 m free fall has a 63 структура м и 52 м рабочая высота. Он несет 32 riders and requires a substantially larger structural and electrical package than the rotating towers.

02

Why is the 35 m tower only 32.4 м высота?

The model name is a commercial label. The engineering structure height is 32.4 m and the operating height is 28.5 м. Use the approved drawing for foundation, clearance and approval work.

03

What height will the authority approve?

It varies by location. Confirm zoning, local amusement-device rules, airport or flight-path limits, heritage sightlines, property requirements and the exact measurement reference before selecting a model.

04

Can the 15 m tower be installed indoors?

It can be evaluated for a covered site, but the finished clear height must allow for the full 16.9 m structure plus installation, maintenance and roof obstructions. Floor loading, access and evacuation also need approval.

05

How much more land does a taller tower need?

The listed footprints grow from 8 х 8 м до 15 х 15 м, but the complete site envelope also includes fencing, очередь, gates, maintenance, emergency access, foundation projection and lifting space.

06

How much power does each height need?

The rotating towers use 40 кВт, 70 кВт и 90 установленная мощность кВт. The free fall uses 520 кВт. The local electrical design must include lighting and control equipment as well as the ride drive.

07

Can we extend a tower after installation?

Нет. An installed tower should not be extended as a field modification. Choose the final height before production because structure, водить машину, фундамент, inspection and planning approval are all tied to it.

08

What should we send for a height review?

Отправить страну, site plan, boundary dimensions, maximum permitted height, intended location, ground conditions, available power and target opening date. We will confirm the models that fit and the information needed for local approval.

Следующий шаг

Отправить сюжет, maximum permitted height, finished clear height if the ride will be covered, ground conditions and electrical capacity. We will return the feasible tower or free fall models with their structure heights and the technical information needed for your local approval process.

Compare the complete drop tower and free fall range, review the four-model comparison, or continue to drop tower power requirements.

ЧТО ВКЛЮЧИТЬ
  • Страна
  • Размер или план сайта
  • Крытый или открытый
  • Поездки, которые вы имеете в виду
  • Дата открытия

Предпочитаю поговорить? Напишите нам в WhatsApp, или по электронной почте [email protected]

Контактная форма 1

Получить бесплатную цену

Расскажите нам о своем проекте

Заполните данные ниже, и мы вышлем вам соответствующую информацию о продукте и предложение..

БОЛЬШЕ РЕСУРСОВ